3051N Smart Pressure Transmitter for Nuclear Service

Maximize installation and application flexibility  with the coplanar platform

■ Improve reliability and performance with integrated DP Flow meters, DP Level solutions, and integral manifolds.

■ Easy installation with all solutions fully assembled, leak-tested, and calibrated.

■ Meet your application needs with an unsurpassed offering.

Proven best-in-class performance, reliability, and safety

■ More than seven million installed

■ Reference accuracy 0.04 percent of span

■ Installed total performance of 0.14 percent of span

■ 10-year stability of 0.2 percent of URL

■ SIL2/3 certified (IEC 61508)

More Info

■ Rosemount Coplanarplat formenables integration of primary elements,manifolds,and remoteseal solutions

■ Best in Class performance with up to 0.05% high accuracy option

■ IEC 62591(WirelessHART®)Protocol enables cost effective installations

■ Local Operator Interface (LOI) offers easy to use configuration capabilities at the transmitter

■ Protocols available include HART®4–20mA,FOUNDATIONFieldbus,PROFIBUS®PA,HART1–5VdcLow Power

■ Selectable HART Revision prepares your plant for the latest HART capabilities while ensuring seamless integration with today's systems

■ SIL2/3safety certification to IEC61508 is available with the full 4–20mA HART offering to simplify compliance

This product data sheet covers HART, Wireless, FOUNDATION Fieldbus, and PROFIBUS PA Protocolsunless specified.

Conformance to specification (±3s[sigma])

Technology leadership, advanced manufacturingtechniques, and statistical process control ensure specification conformance toat least ±3s.

Reference accuracy

Stated reference accuracy equations include terminal based linearity, hysteresis, and repeatability. For Wireless,FOUNDATION Fieldbus, and PROFIBUS PA devices, use calibrated range in place of span.

Models

Standard

High performance option, P8

Rosemount 2051C

 

 

Range 1

±0.10% of span

For spans less than 15:1, accuracy =

±æ0.025+0.005  --U----R---L---ö %ofspan

è                        Spanø

 

 

N/A

 

 

N/A

 

 

Ranges 2–4

 

±0.065% of span

For spans less than 10:1, accuracy =

±æ0.025+0.005  --U----R---L---ö %ofspan

è                        Spanø

 

 

Ranges 2–4

High accuracy option, P8

±0.05% of span

For spans less than 10:1(1), accuracy =

±æ0.015+0.005  --U-----R---L---  ö %ofspan

è                        Spanø

 

 

Range 5

 

±0.075% of span

For spans less than 10:1, accuracy=

±æ0.025+0.005  --U-----R---L---  ö %ofspan

è                        Spanø

 

 

Range 5

High performance option, P8

±0.065% of span

For spans less than 10:1, accuracy=

±æ0.015+0.005  --U----R---L----  ö %ofspan

è                        Spanø

Rosemount 2051T, 2051G

 

 

Ranges 1–4

 

±0.065% of span

For spans less than 10:1, accuracy =

±æ0.0075  --U----R---L---ö %ofspan

è             Spanø

 

 

Ranges 1–4

High accuracy option, P8

±0.05% of span

For spans less than 10:1(1), accuracy =

±æ0.0075  --U----R---L----  ö %ofspan

è             Spanø

 

Range 5(2)

±0.075% of span

For spans less than 10:1, accuracy =

±æ0.0075  --U----R---L---ö %ofspan

è             Spanø

 

N/A

 

N/A

Rosemount 2051L

 

Ranges 2–4

±0.075% of span

For spans less than 10:1, accuracy =

±æ0.025+0.005  --U-----R---L---  ö %ofspan

è                        Spanø

 

N/A

 

N/A

 1. For protocol code F,  accuracy specification is for spans less than 7:1. Not available with out put codeW.

 2. Rosemount 2051G is not available with Range5.

Consultation online
Consultation online

About Us

We, Tianjin Seles Electromechanical Technology Co., LTD, are a high-tech enterprise located in Tianjin Binhai New Area. We are supplier, distributor, wholesaler & trader of Emerson Mass Flowmeter. Products model included in this range are CMF010,CMF025,CMF050,CMF100,CMF200,CMF300,CMF400; F025,F050,F100,F200,F300,F400.